Sub zero 561 ice maker not working

I have a Sub-Zero 532 about 17 years old. A lock icon will signal that the dispenser is locked. Refrigerator ice maker not working. An average glass holds about 10-12 ice cubes. If the arm will not lower, do not force it, as it could break the arm. Older 500, 600, and 700 Series models have a fill adjustment, and most are made on the ice maker itself. Ice jams are another reason for a Sub-Zero 650 ice maker not working. If the fan blade does not turn freely, replace the fan Unload some of the contents of the door shelves and see if the closure improves. Dispenser will meter and collect ice before dispensing into glass. As the ice maker produces ice, a small amount of slushy water is generated as it’s harvested. Sub-Zero recommends manually defrosting the freezer to melt the fill tube obstruction. May 16, 2007 · >Electric< Large Kitchen and Home Appliances - Sub Zero Icemaker- No Ice - Hi; I know that this is a current theme here but I have a bit of a problem and a search gave me negative results. If the arm is locked in the "up" position, firmly press down on the arm to lower it. Apr 3, 2024 · Issue: Your Sub-Zero ice maker fails to produce ice. The most noticeable difference is the ice maker rudder or control arm. The ice maker leaks water from the right hand side of the ice maker when water is filling. This rebate offering changes slightly from quarter to quarter I have a Sub-Zero 532 about 17 years old. Sep 14, 2012 · Ice Maker Replacement Part Designed as a direct replacement for Sub-Zero Modular icemaker 4200520. Step 1: Turn Off The Unit. Confirm bulk ice works. The Refrig/freezer is Sub Zero Model #561. 80k. If the evaporator fan is not working, the freezer or refrigerator will not cool adequately. Don’t let a Sub-Zero ice maker not making ice keep you from On an electronic control panel, 38°F is the recommended setting. In-unit ice makers will stop producing ice once the bucket is full. Genuine OEM Part # 5303918277 | RC Item # 941760. Troubleshooting Common Sub Zero Ice Maker Problems. This replacement part is compatible with various refrigerator models and can fix issues with the icemaker, allowing for easy access to ice. Verify the unit's condenser has been cleaned within the last 6-12 months. Verify the dispenser is not locked: Classic Series Dispenser Lock Operation. Designer Series (IT, IC, DET, DEC): Steps for enabling ice maker operation and addressing specific ice-making challenges. For a limited time, Sub Zero is offering up to $500 credit to customers who upgrade their 500 or 600 series refrigerator to a new built in refrigerator. This may occur if the freezer door is left open. key pad on the Control Center. 110. if needed. Instructions for turning the ice maker on/off and troubleshooting ice production issues. Cause: Possible jammed ice cube. Customer Care and Support. Mar 4, 2022 · A Sub-Zero ice maker that isn’t producing ice may usually be rectified with a simple fix or routine maintenance due to the brand’s high-quality reputation. I can here my ice maker water valve clicking when I turn the switch on but no water fills the unit. The ice maker graphics may fade over time, making it hard to read. Make sure ice maker is on. Replace with a new 25-watt appliance bulb by twisting it clockwise to lock in place. To fix this, you’ll need to thaw the waterline. To turn off, push the toggle switch to the right, as indicated in the image below. You can also view diagrams and manuals, review common problems that may help answer your questions, watch related videos, read insightful articles or use our repair help guide to get started. Verify the mullion chute door that delivers ice from the freezer to the dispenser operates freely (opens and closes). If the ice maker cycles 20 times without the door opening and closing, it automatically turns off. Check valve operation with test cord, if doesn't open, replace. For additional assistance, please contact our customer service number at 1-800-269-2609, 24 hours a day, seven days a week or send us a message using the live chat Manuals and User Guides for Sub-Zero 561 Side-By-Side Refrigerator. Verify the ice maker is on: Press the Ice On/Off key. HE … read more View and Download Sub-Zero 500 Series technical service/training manual online. 542 AND 561 FEATURES 3--13) Pull-OutIce Drawer / Automatic Ice Maker 14) Lighted Freezer Control 15) Ice Maker On/Off Switch 16) Adjustable Wire Shelves­ Freezer (Model 542 has three shelves) 17) Serial and Model Number Plate 18) Hermetically Sealed Refrigeralion Units 19) Fronl Venting allows unil to be completely built-in MODEL 532 7) Deluxe The ice maker and water valve will make noise during operation. 500 Series freezer pdf manual download. If the Sub-Zero ice maker is making ice, but it’s not coming Dec 22, 2023 · If the temperature is below zero, the ice maker’s water supply has likely frozen and the freezer will need to thaw out for several hours. May 3, 2022 · Another common reason that your Sub-Zero ice maker may not be making ice is due to clogged or dirty water filters. May 3, 2022 · Clogged or dirty water filters. WATER. Sub-zero 511 Bottom-mount Refrigerator Pdf User Manuals. , If the water valve in the home is You Save 13%! Your model SUB-ZERO 561 uses the Sub Zero 4200520 Replacement Ice Maker. Damaged door gasket: a ripped or cracked gasket won’t properly seal the freezer door The ice maker in your Sub-Zero freezer is fully automatic and has been tested at the factory. Initiate Fault Code Mode - Press and Hold a COLDER Key, Then the POWER Key Figure 7-2. com Jun 14, 2017 · Check whether the fill tube is frozen. Turn the unit off, and if the arm is up, push down gently. Incorrect or damaged ice maker settings. Next, inspect the water inlet valve for any clogs or malfunctions. I have a Sub Zero, side by side, Model 561, serial # P652067, refridgerator. we have an automatic ice cube maker I emptied ice rack, and returned the rack to the freezer the ice maker has not made cubes since the rack was returned. Water pressure is not a problem, we have replaced the water inlet valve and also adjusted the control unit (turning the plastic switch clockwise) to no avail. Side Panel Installation. Verify the door closes and was not left ajar for a long time. If you don’t find continuity, replace the start relay. SZ4200520 is designed to meet or exceed OEM specifications. 6 oz of ice, or 8 ice cubes, per harvest (each cube is 0. Answer: In Sub-Zero models 532, 542, and 561, the ice maker on/off switch is on the right side of the control panel in the freezer section. Oct 15, 2023 · Hello I have a sub zero refrigerator 561 model and we clean freezer side, we remove the ice maker and the temperature switch, now when we put it back it won't work all of the connection we removed we put it back. The refrigerator's main control board controls the voltage being sent to the ice maker. Reset unit. If your Sub-Zero ice maker is not working properly, it may be due to incorrect or Mar 25, 2022 · Most of the time it isn't the water valve sticking but the ice maker freezing in places it shouldn't and then thawing and then leaking. If the valve is faulty, consider replacing it. A lot of refrigerator brands have this issue from time to time and there are some work arounds for some, but most are perfectly fine just thawing them completely and then it doesn't happen again for years before it builds up the extra frost and ice again. The display on the freezer side was toggling between -3 and the number 40I turned the unit off and shut the breaker off for 1 minute t … read more Press and hold to dispense ice. If one is broken, the gear can move away from the front of the module and cause it to stop producing ice. Clean the Condenser as needed. Since the compressor powers the freezer Nov 2, 2009 · On the ice maker in your Sub-Zero, they use what is called the whirlpool icemaker, The problem that causes this is to little of a water fill and the ice maker then cycles to soon before the ice is completely frozen, the most likely cause of this it the water valve in the home getting clogged up and not allowing eneough water in to fill all 8 cubes completely. The design of this switch is to allow the icemaker and ice dispenser to be shut off for extended vacation Sep 22, 2023 · Here are the steps you can take to reset your Sub Zero ice maker quickly and easily. Fortunately, simple repairs like changing the water filter or adjusting to the freezer temperature can often help solve the problem and restore your ice maker’s functionality. 9. Initiate Diagnostic Mode - Press and Hold a COLDER Key, Then the POWER Key LIGHTS ICE MAKER MAX ICE COLDER WARMER COLDER ALARM POWER WARMER PURE AIR Figure 7-3. If it is a new installation, confirm the water line is connected to the unit. Plastic ice maker control arm attaches directly to the metal shutoff arm. Turn the knob to zero (0) or off for units with a dial control. Make sure the ice maker is free of obstructions or jammed ice cubes. This ice maker assembly is a modular 8 cube icemaker with a heavy duty ice rake and module. $176. Ice maker did not fill. Check thermostat. . ADD TO CART. For dial control units, turn the control down past 1 to the "off" position. You recently advised me on my Sub Zero 561 and I really appreciated your help. For those ready to tackle maintenance or repairs, our comprehensive parts diagrams and manuals offer detailed insights into your Sub Zero model 532’s anatomy. Answer: All Sub-Zero in-unit ice makers produce eight cubes of ice every 2-3 hours on average. Troubleshooting: After the unit is turned on, wait 24 hours for ice production. If not, turn the ice maker on. Empty the ice bin and monitor the dispenser operation after new ice is made to see if the issue is resolved. In addition, check to see if frost has accumulated on the evaporator coils. Please handle carefully. These filters need to be regularly cleaned and maintained to ensure optimal operation of the ice maker unit. Free Resources for DIY Repairs. 6-8 glasses of ice will empty the bucket after 24 hours of ice production. The fill tube was solid ice, so I melted it with a blow drier and a large piece drained out. Verify freezer setpoint is 00°F or lower. Low water pressure can allow the water in the fill tube to freeze, preventing flow to the ice maker. Verify doors and door seals are free of tears and debris. The ice bin may take 1-2 days to fill completely. 01 - Sub Zero Refrigerator Main Control Board. Filter results by category, title and symptom. Low water pressure. Return the light diffuser to its place by pushing it down in its slots. Wait for half an hour to see if the unit restarts. Skill Level. It may take this long to see ice cubes in the ice bin. Make sure it is level and seated in place. Installed both. Refer to Manually Defrost a Sub-Zero for instructions. Let 24 hours pass, and then check for ice Model 590 icemakers are turned on and off with an on/off switch. Jun 30, 2019 · QUICK AND EASY APPLIANCE DIY REPAIR VIDEOS – SAVE BIG $$$ BY FIXING IT YOURSELF If the video was helpful, remember to give it a Thumbs Up 👍 and consider S Troubleshooting: Clean the Condenser. If "Service Ice" is flashing, the water valve energized longer than fifteen seconds and the ice maker turned off. All you'll need is your the serial number from your old Sub-Zero refrigerator. Verify ice maker shut-off arm is in the down position. If the dispenser has a ‘Lock’ button: A quick 3-second press and hold of the ‘Lock’ button will lock the dispenser. See also, Sub-Zero Door and Drawer Self-Closing Operation. Solution: Start by checking the water supply line to ensure it’s not kinked or blocked. Ice makers produce 4. If the freezer temperature is too high, ensure If it is not making ice, see Ice Maker Does Not Make Ice. If unit does not dispense ice after 5 seconds, see Sub-Zero External Ice Dispenser Not Working. The original problem was that ice maker was not Nov 5, 2021 · Watch the video to see the repair and learn how to replace yours. I uninstalled the ice maker because of a smokey s … read more 09 - Sub Zero Refrigerator Auger Motor. It would deposit ice cubes into the bucket and then water will overflow into the bucket (about 1 cup). Remove the old bulb at the top of the drawer compartment by twisting counterclockwise. :cool: I removed and checked for leaks or cracks. Watch on. 49. But if you still can't fix the problem, you may want to research the problem further by visiting the Sub-Zero website to find a service provider or by calling Sub-Zero product support at 1-800-222-7820. Sep 14, 2010 · Hi Sub Zero 561 I had to replace my leaking ice maker water line in the basement. If the fan motor has failed and isn't running, the temperature will rise high enough that the ice maker will be unable to make ice. This would cover about 30 years of fridges from the 80's until about 2008. It is a 500 series, the model that has the freezer temp control on the left side of ice maker and ice … read more Apr 1, 2020 · Lastly, a Sub-Zero 650 not making ice could be due to warm freezer temperatures. The auger motor spins the auger blade and pushes the ice through the dispenser chute. 1 is warmest, and 10 is coldest. View online or download Sub-zero 511 Bottom-mount Refrigerator Technical Service/Training Manual, Information Manual, Installation Instructions Manual. Here's a new one: The ice maker is not making ice! It was replaced in 2007. Additionally, if the start relay has a burnt smell, replace it. The word ICE will appear next to the freezer temperature readout on the LCD display screen to indicate the ice maker is ON. This high-quality part, Model No. How to replace the ice maker system on your sub-zero refrigerator and add a filter. Sub-Zero ice maker troubleshooting tips include placing the ice bucket so it makes contact with rear switches and defrosting a frozen fill tube The ice maker is turned on and off by touching the Ice On/Off key on the control panel. Feb 27, 2022 · Sometimes, when the ice-dispenser in the door of a Sub-Zero Refrigerator/Freezer isn't used often enough, and/or ice isn't removed from the freezer's ice tra Sub-Zero Classic Series (BI) Control Panel Icons, Symbols, and Buttons; Legacy Designer Series Control Panel Icons, Symbols, and Buttons; Sub-Zero Control Panel Does Not Work; Sub-Zero Control Display Is Dark; Turn Sub-Zero Ice Maker On or Off; Sub-Zero Light Terminators if the door was left open for an extended period of time. Also for: 501r, 501f, 511, 532, 542, 550, 561, 590. Refer to Turn Off Dial Control Refrigerator or Freezer for more information. How to repair a SubZero Ice Maker that quit making ice. Ice Maker Not Working. If your Sub Zero ice maker has a control panel, turn off the unit at the control panel. If your Sub-Zero ice maker is not working Talk directly to a customer care expert at the Sub-Zero, Wolf, and Cove service center, or connect with an appliance consultant at an official showroom near you. We sell the real thing! Watch Video. 501F 511 532 550 561 590. I don't know what tells the system the tray is full and sto … Dec 5, 2016 · the ice maker in our sub zero has begun to have a problem, ice seems to dump into the tray not completely frozen and the tray becomes a large block of ice. Sub-Zero recommends that any ice maker adjustment be completed by a service technician. Confirm the freezer temperature is at or below 5°F. Confirm the ice maker is turned on at the control panel. You can inspect the board for signs of damage or a shorted component. It’s important to inspect these components to identify the root cause of the issue. Ice maker quit working so I ordered a new one and a new water valve. Additionally, examine the ice mold thermostat and replace it if necessary. The evaporator fan motor draws cold air over the evaporator coils and circulates it throughout the freezer. Jan 12, 2021 · Check that the unit is not in defrost mode. Only get about 4 cubes of ice, the remaining ice forms glaciers on the drawers. If the cycle did not start, remove the icemaker, remove the white square cover on the front and check the two small pins in the center of the gear. For Models 601F, 611, 611G, 650, 650G, 661, 642, 685, 632 and 695, the ice maker system will shut off if the ice bucket is not in place. Water valve energized longer than fifteen seconds. Make sure the ice maker is always left on. Your ice maker freezing up occurs when this water freezes on its prongs, blocking new ice from falling into the ice bin. If you still find your Sub-Zero refrigerator not making ice after the above assessments, you may need to inspect the ice maker. Special Wait five minutes and press the water key for 60 seconds. (Open: 48°F ±6°, Close: 15°F ±3°). Repair if necessary. It may be necessary to defrost the Sub Zero Refrigerator Ice Maker Assembly. Hinge Adjustment. Mar 6, 2024 · 4200520 Ice Maker for Sub Zero Replacing a Built-in Sub Zero Refrigerator: 532, 550, 561, 601R More Sub Zero Refrigerator 561 Parts, Diagrams, Videos Repair Help Repair Clinic Mar 4, 2022 · If your Sub-Zero ice maker isn’t working, it could be because the water line is frozen. Frozen ice maker fill tube. The freezer temperature should be set between 0 and 5 degrees (-18 to -15) for the ice maker to work properly. ) Visually inspect electrical connections at icemaker & valve. En español 1-800-269-2609 24/7 5. If these troubleshooting steps do not resolve the issue, service is necessary to expertly diagnose and repair the product. I think there is a load … read more When an internal ice dispenser on Classic series (BI) units does not dispense: Check if there is ice in the ice bin. The module is poduced by Whirlpool for SubZero and can be found here. 500 Series, 600 Series, and Classic Series. Run a test of the continuity of the relay between the start and run terminals. Various ice maker components may require adjustments or replacements to function properly. Verify the water supply is turned on. Undercounter Ice Makers produce a batch of ice as often as every 20 minutes and continue to make noise as they Sep 9, 2009 · My sub zero, installed in 1991, has stopped making ice. It’s recommended that you change your refrigerator’s water filter at least every 6 months to prevent clogs. On some models, the ice bin presses the ice maker switch. If held longer, the cycle repeats for more ice. Standard ice production cannot be adjusted in any other way. Installation Checklist. If none of these solutions work, it may be time to call a Sub-Zero technician. Contact Factory Certified Service to schedule an appointment for repair. Replace icemaker if defective. After freeing obstructions, turn the unit off, then on again to reset. Apr 28, 2022 · This was a new icemaker installed on a sub zero 532 unit from 1988. Warm freezer temperature. If a Sub-Zero ice maker is not making ice, it can be upsetting knowing its high quality. Reviews. The ice maker arm only moves an inch. Shutoff might be found: View online or download Sub-zero 501F Technical Service/Training Manual, Service Manual, Information Manual, Installation Instructions Manual Ice Maker Operation Jul 1, 2021 · Step 4: Inspect the Ice Maker. For products with the Max Ice feature, the noises will occur more often when the Max Ice feature is turned on. The more ice dispensed, the less it will clump Answer: Ice maker water fill adjustments vary by ice maker model. I uninstalled the ice maker because of a smokey s … read more If icemaker starts & finishes cycle: (NOTE: If >15°F, icemaker will only complete 1 revolution. Check that ice isn’t obstructing the exit from the ice maker. If the arm is down, next check the fill tube. The refrigerator ice maker compartment fan motor assists in keeping the air temperature in the compartment cold enough for the ice maker to make ice. To start making ice, activate the ICE ON/OFF. Here are 5 reasons why your Sub Zero Ice Maker is not working. The freezer temperature should be set between 0 and 5 degrees Fahrenheit (-18 to -15C) for the ice maker to work properly. Another common reason that your Sub-Zero ice maker may not be making ice is due to clogged or dirty water filters. The word "ICE" shows when the ice maker is on. The Sub Zero 4200520 Replacement Ice Maker is an ice maker replacement that fits several refrigerator models from Sub-Zero. Verify the ice maker water fill tube is not blocked. Here are the most common reasons your Sub Zero refrigerator's ice and water dispenser isn't working - and the parts & instructions to fix the problem yourself. For metered ice, press and hold for 2 seconds. See Refrigerator and Freezer Temperature Settings. The water dispenser is disabled while Sabbath Mode is active. These common causes, from warm freezer temperatures to dirty condenser coils, generally have a simple solution. We have 7 Sub-Zero 561 Side-By-Side Refrigerator manuals available for free PDF download: Technical Service/Training Manual, Use & Care Manual, Use And Care Manual, Information Manual, Installation Manual, Installation Instructions Manual. Refer to the images below for ice maker arms in different models. Ice will dispense within 3 seconds. These factors can contribute to increased temperatures, prohibiting ice production: Temperature is set above 5°F: the freezer needs to be below 5°F to adequately produce ice. The first step in resetting your Sub Zero ice maker is to turn off the unit. Common reasons for a Sub Zero ice maker to stop working include a faulty water inlet valve, a clogged water filter, a malfunctioning ice maker assembly, or a problem with the temperature control. Start Relay. I've just read it may be I don't have enough water pressure to the line. the ice maker just stopped working. Jul 1, 2023 · To disengage the lock, simply press and hold ‘Light’ for another 5 seconds. Jun 1, 2020 · Sub-Zero Water Filter is Dirty. If the control board is defective, the ice maker may not work at all. The water must be turned on. Step Mar 6, 2024 · Get A Quote. Ice maker does not work. When this happens, you’ll find your Sub-Zero ice maker not making ice due to a lack of water supply. When the switch is on, the icemaker system light will be illuminated. The Sub-Zero 4200520 is a bare ic. If the water is going to be turned off to the home for an extended vacation, turn the ice maker off first, and then the home water supply. The freezer will need to be emptied and the fridge Feb 4, 2019 · Hi, Appliance Medic. 11:14. Ice production for Classic (BI) and Designer (IT, IC, ID) models may be temporarily increased by initiating the Max Ice feature. It appears the water is leaking from the bottom right hand side of the ice maker, near the thermal loop but again, no visible Jan 4, 2022 · Ask your local dealer about available promotions. You can also view 561 parts diagrams and manuals, watch related videos or review common problems that may help answer your questions to get started on fixing your Refrigerator model. HE … Aug 6, 2021 · This video shows how to replace a ice maker water valve on a Sub-Zero refrigerator. And much more. I understand the water line can freeze up. If I empty the tray it takes about 2 days to … read more Jan 1, 2021 · Pull the diffuser outward to remove it. 01 - Freezer Temperature is Above 10 Degrees F (-12C) If the freezer temperature is above 10 degrees Fahrenheit (-12C), the ice maker will not produce ice cubes efficiently. 575 oz) every 2-3 hours. If the unit is not properly leveled, the soft close feature may not work properly. Make sure the unit is turned on for at least 24 hours, as ice makers may not cycle until 24 hours pass. To determine if the auger motor is defective, pull out the ice bucket and turn the bucket auger by hand. Related Videos for Sub Zero Refrigerator Model 550. When I turned the unit on no water. PRO Series, 648PRO, 700 Series, 600 Series, 500 Series, Undercounter Units (DEU, UC-24CI, 315I): If your Sub-Zero freezer is not freezing, check the following freezer parts for fault: 1. The fill tube is a thin tube located above the ice maker, coming from either the back or side wall. Sub-Zero refrigerators will periodically shut off the cooling unit to allow for de-icing. Check the following: The ice maker is turned on at the control panel. If the unit's installation and food load is not the issue, no further troubleshooting advice is available. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. Jul 1, 2021 · This is more likely to occur when there is low water pressure to the water inlet valve. March 6, 2024 Oct 1, 2019 · Edgewater Parts 7002738 Ice Maker Compatible With Sub-Zero Refrigerator ; 8 Cube; Harness And Arm Included ; For Models: 532, 542, 561, 601F, 632, 642 ; 1 Year Warranty ; MONEY-BACK GUARANTEE - For Any Reason You're Not Completely Satisfied, You Can Ask For A Replacement Or Full Refund, No Questions Asked. For images of the control arms, refer to Ice Maker Control Arm Will Not Lower. If these troubleshooting steps do not resolve Apr 10, 2016 · My Sub-zero 561 icemaker is overflowing. Warm temperatures impact ice maker performance. LIGHTS ICE MAKER MAX ICE COLDER WARMER COLDER ALARM POWER WARMER PURE AIR Figure 7-1. The ice maker is connected to your water supply and operating properly. It may be necessary to defrost the freezer to clear the ice maker. To disable the lock, give the ‘Lock’ button another 3-second press and hold. This is a very similar repair that would be done to a 200, 300, 500, 600, 700 series Unit. Get quick answers online, or reach a certified service provider or installer. Shake the bucket or tap the side of it to loosen the ice. Troubleshooting: If no ice is produced: Verify the ice maker is turned on. See full list on homealliance. If there is ice in the bucket, verify it is not frozen or stuck together. What else could I do Thanks Tony Oct 2, 2014 · I have a sub zero 642, the water won't stop when filling ice maker. Sub-Zero ice makers are of two different designs. The old whirlpool style icemaker was beginning to peel. Make sure the door or drawer has opened and closed recently. For a dial control, set the dial between 4 and 6. Here’s how to inspect the ice maker: Check the shut-off arm: The arm must be in the down Feb 29, 2024 · A. If the freezer temperature is too high, ensure that the condenser coils are clear of debris and the condenser fan is working properly. This switch is located in the refrigerator section on the right hand side of the Control Panel Assembly. At Repair Clinic, we provide more than just high-quality Sub Zero 532 parts; we offer tons of free resources designed to support your DIY repair journey. On average, these noises may be heard every 2-3 hours. We installed a fresh replacement May 1, 2020 · Ice Maker is Jammed. Troubleshooting: After the unit turns on, wait 24 hours for ice production. You can also use a multimeter to determine if voltage is reaching the In the Options menu, ice cube (s) are highlighted if on. Aug 1, 2020 · I have a sub zero 648 pro. If bulk ice does not work, the ice bin may be out of place. If the auger motor is burned out or defective, the ice won’t move forward and fall through the chute. Verify the unit is not in Sabbath Mode. Call us at (800) 222-7820. If there is ice in the bin, verify the ice is not clumped together. 200, 300, and 500 Series Sub-Zero products have dial controls. For additional assistance, please contact our customer service number at 1-800-269-2609, 24-hours a day May 27, 2011 · we have an automatic ice cube maker I emptied ice rack, and returned the rack to the freezer the ice maker has not made cubes since the rack was returned. It may take 2 days to fill an ice bin when empty. A Sub-Zero water filter supplies the ice maker with water to make ice. The only thing is I forgot if I put the yellow wire and black wire in the correct orientation in the temperature switch, can someone If the freezer temperature is above 10 degrees Fahrenheit (-12C), the ice maker will not produce ice cubes efficiently. 8. However, if the filter becomes clogged with particles and impurities, water flow can be restricted and result in a lack of ice. kt xq xb da pv pp hk hm rx my